Japan, Kyowa Electronic Instruments Co., Ltd.
Kyowa PS-05KC PS-C Miniature Pressure Sensor
Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model: PS-05KC
The PS-C is a miniature pressure sensor with a strain-gage bridge inside. The cable direction is parallel to the sensor surface.
Features
• Ultra-thin
• Installed by adhesives
• Suitable for distributed pressure measurement by using multiple units
Specifications
Performance
Rated Capacity | 50 kPa |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Rated Output | 0.25 mV/V or more Note: Rated output is sorted to one of the classes divided by every 2% difference in output value. Since the rated output stated in the Test Data Sheet is the center value of the class, it may include a maximum error of ±1%. |
Cable Direction to Sensing Surface | Horizontal |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | 0 to 50ºC |
Temperature Effect on Zero | Within ±0.8% RO/ºC |
Temperature Effect on Output | Within ±0.3%/ºC |
Electrical Characteristics
Safe Excitation | 3 V AC or DC |
---|---|
Recommended Excitation | 1 to 2 V AC or DC |
Input Resistance | 350 Ω ±10% |
Output Resistance | 350 Ω ±10% |
Cable | Polyurethane coated copper wires, 0.1 mm diameter by 5 cm long, bared at the tip |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Natural Frequencies | Approx. 10 kHz |
Weight | Approx. 0.5 g (Excluding cable) |
Materials | Metallic finish |
Dedicated Adhesive | RC-19 (Request the RC-19 when ordering the transducer.Cost option) |
Compliance | Directive 2011/65/EU, (EU) 2015/863 (10 restricted substances) (RoHS) |
Dimensions
Remarks
(Note 1) Copper alloy is used for liquid-contacting part.
Avoid measuring corrosive liquid or gas.
(Note 2) Epoxy adhesive has been used to assemble the liquid-contacting part.
Avoid measuring organic solvent (toluene, ketone, etc.).
(Note 3) Measuring liquids of 20 to 70K are limited to oil.