Japan, Kyowa Electronic Instruments Co., Ltd.
Kyowa PSS-02KAF PSS Miniature Pressure Sensor
Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model: PSS-02KAF
The PSS is a miniature pressure sensor with a strain-gage bridge inside. Thin-film strain gages are directly formed on the diaphragm.
Features
• Ultra-thin
• Installed by adhesives
• Suitable for distributed pressure measurement by using multiple units
Specifications
Performance
Rated Capacity | 20 kPa |
---|---|
Nonlinearity | Within ±3% RO |
Hysteresis | Within ±3% RO |
Repeatability | 1% or less |
Rated Output | 0.75 mV/V or more Note: Rated output is sorted to one of the classes divided by every 2% difference in output value. Since the rated output stated in the Test Data Sheet is the center value of the class, it may have a maximum error of ±1%. |
Cable Direction to Sensing Surface | Horizontal |
Environmental Characteristics
Safe Temperature | -20 to 70ºC (Non-condensing) |
---|---|
Compensated Temperature | 0 to 50ºC (Non-condensing) |
Temperature Effect on Zero | Within ±0.6% RO/ºC |
Temperature Effect on Output | Within ±0.5%/ºC |
Electrical Characteristics
Safe Excitation | 4 V AC or DC |
---|---|
Recommended Excitation | 1 to 2 V AC or DC |
Input Resistance | 350 to 1000 Ω |
Output Resistance | 350 to 1000 Ω |
Initial Unbalance | Within 2.5 mV/V (5000 ×10-6 strain) |
Cable | Polyurethane coated copper wires, 0.08 mm diameter by 5 cm long, bared at the tip |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Natural Frequencies | Approx. 6 kHz |
Weight | Approx. 0.15 g (Excluding cable) |
Dedicated Adhesive | RC-19 (Request the RC-19 when ordering the transducer.Cost option) |
Dimensions
To Ensure Safe Usage
High-carrier-based dynamic strain amplifier DPM-912,913 or 952 may not satisfy the specified rated output insome rare case.
Use dynamic strain amplifier DPM-911,951, signal conditioner CDV-900A or request us to
calibrate the transducer in combination with the strain amplifier.
Remarks
(Note 1) Copper alloy is used for liquid-contacting part.
Avoid measuring corrosive liquid or gas.
(Note 2) An epoxy adhesive is used to assemble the liquid-contacting part.
Therefore, avoid using the sensor to measure organic solvents (Toluene, ketone, etc.)
(Note 3) It should not be used under high temperature and high humidity environments for a long time.
(Note 4) It should not be used under water.
Related Products
-
Kyowa G-MATE-C Gauge Mate Gauge pressurization Tools gauge mate
-
TONE HATXE409 Torx Socket Set for Impact Wrench (with Socket Holder)
-
KETT ELECTRIC LABORATORY TX-200 Grainscope
-
Saitamaseiki AK-130 Die grinders and Y-Brush
-
Chiyoda Seiki EX-300mkII – G2, G3 Second-stage Decompression Type Pressure Regulator For Equipment/line/panel Mount (Primary pressure: 20.0 MPa or less / Adjustment pressure: 0.1 to 0.6 MPa, Maximum flow rate: 50 L, 150 L/min-Air)
-
Shimizu Weeding Claw – Gardening Product