Line Seiki E10 Series Preset Counter

Product Made in Japan
Manufacturer: Line Seiki
Model: E10 Series

E10 Series Preset Counter

Model

Description

The E10 Series offers a dependable DIN-sized 72 x 72 preset counter with a single level. It features a 6-digit Red LED display, with each figure measuring 10.16 x 5.54mm. This counter is highly reliable and accepts either Contact or Open Collector input signals. It can perform counting in both addition and subtraction modes, as well as bidirectional counting (Quadrature) at speeds of up to 10kHz. When the preset value is reached, the counter triggers a built-in relay. You can set preset values using the digital switches on the front panel. The unit is powered by selectable voltage options of 100/110V or 200/220VAC.

Specification

Display 6 Digits 7-Segment Red LED 10.16 mm (H) x 5.54 mm (W)
Power Source 100/110 VAC or 200/220 VAC, 50/60 Hz
Power Consumption 4.3 VA
Preset Level 1 Level
Setting Range 0 – 999999 *
Input Mode Open Collector Input L : 0 to 2 V (sink current 7mA max.)

Contact Input: Relay, Microswitch, etc. (sink current 7mA max.)

Count Mode 90°Quadrature Input / Individual Add/Subtract Input

(simultaneous input of add and subtract is not possible)

Count Speed Open Collector Input: 10kHz / Contact Input: 30Hz
Pulse Width Open Collector Input:50µs / Contact Input: 16.6ms
Duty 1 : 1
Output Relay Type 1C, 250 VAC, 2A (125VA), 220 VDC 2A (60W) cosФ = 1
Output Display Red LED (ON when output is actuated)
Output Time 0.1 to 1second per shot (adjustable via front panel knob) or latch output
Reset Input Contact (100 ms min.)

Open Collector (sink current 10mA max.)

Reset Mode Remote Reset, Auto-Reset, Front Panel Reset (E10-166MR)
Operation Mode Auto-reset (display resets when the preset value is reached)

Overrun (counting continues even after the preset value is reached)

Memory E²PROM Data Retention: approximately 20 years

Memory Frequency: 100,000 times max.

Power Source for Sensor 12 VDC, 60mA max.
Operating Temperature -10 to +50°C (should not be frozen)
Operating Humidity 35 to 85 % RH (non-condensing)
Hi-pot Test 1500 VAC (1minute)
Insulation Resistance 100 MΩmin. (500 VDC Megger)

(on Power leads and between non-charged metal parts)

Noise Immunity Square wave noise from Noise Simulator

±2.0kV (PowerTerminals),±500V(Input Terminals)

Vibration Immunity Malfunction: 10 to 55 Hz, double amplitude 0.5mm

Destruction: 16.7 Hz, double amplitude 4mm

Shock Immunity Malfunction: 100 m/s²(10G) Destruction: 300 m/s²(30G)
Weight 550g
* When set to 0, the counter will count down from displayed value to 0, when output signal occurs.

Front Panel (E10-166MR)

Wiring

Operation Mode Selection

A: Auto-reset, one-shot output.
B: Overrun, one-shot output.
C: Overrun, latch output.

Adjustment of Output time

When you choose operation mode A or B, you can change the output duration between 0.1 to 1 second by rotating the knob located beneath the slide switch.

Operating Example

Dimension

Application

Counters have versatile applications, including counting, sorting, and packaging products. They are also valuable in cutting materials like textiles, paper, and plastic film to specific lengths. Additionally, counters, when paired with rotary encoders, are effective tools for measuring the length of textiles, paper, and plastic film.

Caution

• The counter won’t respond to count or reset signals for the first 100 ms after powering up.
• If you choose Individual Add/Subtract Input, you can’t input additive and subtractive signals simultaneously.
• Make sure to use shielded wires for input and output connections.
• Try to keep input/output wires separated from power wires as much as possible.
• Keep wires for short circuits (jumpers) as brief as you can.
• If you notice noise on input or power wires, consider using a noise suppressor or a power source noise filter.

Dustproof Cover (Optional)

  • If you plan to use the counter in harsh environmental conditions like dust or splashes, it’s advisable to use a protective dustproof cover. If you use the cover, make sure the panel cutout is 70 x 70 mm.

Other items of Line Seiki

Request the quotation for Line Seiki

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top