Magnescale MJ100/MJ110 Ribbon Type Scale (Digiruler)

Made in Japan
Manufacturer: Magnescale Co., Ltd.
Model: MJ100/MJ110

Features

  • Capable of 40 to 1000 divisions
  • Produces AB quadrature signals with a resolution from 2 μm to 125 μm, when used in combination with the optionally available
    Use the DigirulerR PL25 head unit with the SL110/130 scale unit (signal wavelength: 5 mm), or the PL60 with the SL331 scale unit (signal wavelength: 2 mm).
  • Supply voltage 5 V input, Line driver (EIA-422 compliance) output
  • Voltage 12 to 30 V input, Open collector (lOL=50 mA maximum) output
  • MJ100 also generates U/ V/ W phase output with a period of reproduced DigirulerR signal (5 mm with PL25; 2 mm with PL60)

Specifications

MJ100/MJ110

Specifications
*1 These valuse for a minimum phase difference of 1 μs may vary depending on the output cable length.
*2 The alarm function may not operate when an abnormal offset is generated due to a broken wire, etc
ModelMJ100MJ110
Power supplyPower supply voltageDC5 V (4.5 V to 6 V)DC12 V to 30 V (11 V to 31 V)
Power consumption4W3W
Output interfaceLine driver (EIA-422 compliance)NPN open collector(IOL=50mA max.)
OutputAB quadrature・Z phase・UVW phases・AlarmAB quadrature・Z phase・Alarm
Number of divisions1000, 960, 800, 512, 500, 480, 400, 256, 240, 200, 128, 120, 100, 80, 64, 40 and 1/2 of each of these (which does not satisfy the synchronized reference point specifications.)
Maximum response speed1000 divisions6 kHz:when connected to PL25 1800 m/min when connected to PL60 720 m/min600 Hz:when connected to PL25 180 m/min when connected to PL60 72 m/min*1
500 divisions15kHz:when connected to PL25 4500m/min when connected to PL60 1800m/min1.5 kHz:when connected to PL25 450 m/min when connected to PL60 180 m/min*1
200divisions42kHz:when connected to PL25 12600 m/min when connected to PL60 5000 m/min4.2 kHz:when connected to PL25 1260 m/min when connected to PL60 500 m/min*1
120 divisions70 kHz:when connected to PL25 21000m/min when connected to PL60 8400 m/min7.4 kHz:when connected to PL25 2220m/min when connected to PL60 888 m/min*1
Phase difference100 ns1 μs
Alarm*2Speed alarm (minimum phase difference time or maximum response frequency); Level alarm (0.4 Vp-p or less); Minimum alarm time: approximately 400 ms
System startup timeWithin 0.5 seconds after the power comes on line
Compatible head unitPL25 or PL60
Operating temperature0°C to 45°C
Storage temperature-20°C to 60°C
Dimensions138×93×26 (mm) ncluding protrusions
Mass350 g
AccessoriesManual・Output connector・connector cap・mounting screws・Ferrite core
OptionSET-P16-1 (for external reference point) Scale extension cable, external reference point extension cable, Output connector with cable

REQUEST QUOTATION

PAYMENT

payment-methods

Return Top