Japan, Magnescale
Magnescale PL101-RM / RP / RY Ribbon Type Scale (Digiruler)
Made in Japan
Manufacturer: Magnescale Co., Ltd.
Model: PL101-RM / RP / RY
Features
- Detects linear position and displacement when combined with the SL700 series. Produces serial communications compatible with Mitsubishi Electric, Yaskawa Electric or Panasonic.
- Non-contact detection between head and scale
- Magnetic detection system for excellent resistance to dust, oil, vibration and shock
- A wide range of models are available so you can select the best model for your specific application
Specifications
Specifications | |||||||
---|---|---|---|---|---|---|---|
*1 Refer to Dimensions | |||||||
Model name | PL101-RM | PL101-RHM | PL101-RY | PL101-RHY | PL101-RP | PL101-RHP | |
Head unit | PL101-R | PL101-RH | PL101-R | PL101-RH | PL101-R | PL101-RH | |
Protection grade |
IP50 or equivalent |
IP67 or equivalent (not including connector) |
IP50 or equivalent |
IP67 or equivalent (not including connector) |
IP50 or equivalent |
IP67 or equivalent (not including connector) |
|
Reference point |
Available | ||||||
Resolution (number of divisions) |
0.1 µm (1/8000) |
1/8192 | 0.1 µm (1/8000) |
||||
Accuracy (20°C) |
±10L µm *L≦3000 mm ; ±(10L +2.5N) µm *L≦3000 mm *L: Effective length, N: Integer according to length Refer to specification of SL700 about L and N. |
||||||
Clearance*1 | 0.35±0.1 mm | ||||||
Offset | ±0.2 mm | ||||||
Change in attitude |
Pitch*1 | ±0.1° | |||||
Yaw*1 | ±0.2° | ||||||
Roll*1 | ±0.2° | ||||||
Commnication protocol |
Mitsubishi Electric | Yaskawa Electric | Panasonic | ||||
Output sginal | 1 Vp-p analog output differential output | ||||||
Power supply voltage | DC 5V±5% | ||||||
Power consumption | Max. 1.0 w | ||||||
Maximum response speed | 10 m/s | ||||||
Head cable length | 300 mm | 3000 mm | |||||
Mass | 60 g | 150 g | |||||
Operating temperature | 0°C to +45°C | ||||||
Storage temperature | -20°C to +50°C | ||||||
Extension cable between head and interpolator (Option) |
CK-T12: 1 m, CK-T13: 3 m, CK-T14: 5 m, CK-T15: 10 m | ||||||
Extension cable between interpolator and servo amplifier (Option) |
CE33-1: 1 m CE33-3: 3 m CE33-5: 5 m CE33-10: 10 m CE33-15: 15 m CE33-20: 20 m |