Osaka Vacuum
Osaka TG2400F Turbo Molecular Pumps

Manufacturer: Osaka Vacuum, Ltd.
Model: TG2400F
Features
- Any orientation
- Compact size
- Energy-saving
- Quick start up
- Quick shut down with gas vent
- Durable structure for air inrush
- Serial communication
※RS232C Serial interface - Certificated safety standard NRTL / SEMI-S2 / CE
Specifications
odel | TG2400F | TG2400F-40 | |
Inlet flange | VG250/ISO-B250 | ||
Volume flow rate | N2 (L/s) | 2400 | |
N2 (with protective screen) (L/s) | 2300 | ||
H2 (L/s) | 1100 | ||
Max. compression ratio | N2 | 1×108 | |
H2 | 1.4×103 | ||
Base pressure | (Pa/Torr) | <1×10-6/<7.5×10-9 | |
Max. throughput※1※2 | (sccm) | 900 | 1500 |
Startup time | (min) | 5-7 | |
Shutdown time | (min) | 15-18 | |
Max. backing pressure | (Pa/Torr) | 200/1.5 | |
Recommended backing vacuum pump | (L/min) | ≧500 | |
Position | Any orientation | ||
Weight (kg) | Air cooling Water cooling | 45 47 | |
Controller | TC2403 | TC2403-10※3 | |
- *1: When using a backing vacuum pump of 1000L/min.
*2: Differs according to the power supply model.
*3: TG2400F-40 - [Ambient temperature for use]
- The ambient temperature range to ensure you reach the ultimate pressure is 10-23℃. The permissible ambient temperature is 10-32℃ for air cooling type and 10-40℃ for water cooling type. The maximum temperature for the cooling water which ensures the ultimate pressure is 30℃ and the allowable temperature range for cooling water is 10-35℃.
Dimensions

| A | B | C | D |
| VG250 | φ350 | 16 | 340 |
| ISO-B250 | φ335 | 16 | 340 |
- Bolt holes for the flange on the intake are arranged symmetrically around the centerline.
Reprinting prohibited without permission. Contents are subject to change without notice.