Japan, Pollution and Environment
OSC92GT100 Freon Gas Detector

Model: OSC02NC104
Features
– Prototype of a reliable detector
– Other gases are cut off by means of multilayer semiconductor
– High sensitivity of 2g/year(R410A)
– Sensor protection function incorporated to cut high density gas
– 3 steps of sensitivity selectable
Purpose of use
– For leakage of refrigerant of car air conditioner, air conditioner, refrigerator, etc.
– Leak check by using freon gas as a tracer gas into general purpose appliances, parts and piping which requires airtight.
– Leak check of retention steam by solvent during work of cleaners by freon solvent
– Flexible tube for extension is supplied as a standard accessory
Specifications
| MODEL | OSC 92GT100 | |||||||
| Place of use | Factories of air conditioner, refrigerator, car air conditioner | |||||||
| Detecting method | semiconductor, suction | |||||||
| Objective gases | R11/R12/R22/R23/R502/R123/R134a R404A/R407C/R410A/R600a | |||||||
| Max sensitivity (g/year) | R12: 6, R22:2, R134a:3, R404A:2, R407C:2, R410A:2, R600a:2 | |||||||
| Sensitivity selection | manual H/M/L | |||||||
| Zero reset | Auto | |||||||
| Dimensions | 66W x 56D x 173H mm | |||||||
| Weight | approx. 400 g | |||||||