Japan, Measuring Instrument
OSC92OT101 Single Component Force Load Cell
Model: OSC92OT101
Features
– High measuring resolution of 1/10000
– High accuracy by matrix operation possible
– High stability against temperature
Specifications
Model | OSC 92OT101 | |||||||||||
Rated output | Approx. 0.75mV/V(approx. 1500×10-6 strain) | |||||||||||
Non-linearity | +/-0.2%FS | |||||||||||
Hysteresis | +/-0.2%FS | |||||||||||
Allowed overload | +/-150%FS (Mechanical stopper shall be applied for any capacity) | |||||||||||
Cross talk | -When the rated load is applied in the Fz direction: +/-1%FS/FS | |||||||||||
-When a load equivalent to the rated load is applied in the -Fz direction to | ||||||||||||
a position which is 30cm below the pressure detection-surface: +/-0.3%FS/FS |
Temperature influence on the zero point | +/-0.01%FS/deg.C | |||||||||||
Temperature influence on the sensitivity | +/-0.05%Reading/deg.C | |||||||||||
Cable connection | NDI connector length = 5m |
Specifications of respective types
Type | Rated load | Fitting Screw d | Weight Approx Kg | |||||
(Allowable load / Allowable moment) | ||||||||
(N) | (N) | (N) | (Nm) | (Nm) | (Nm) | |||
Fx | Fy | Fz | Mx | My | Mz | |||
-10N | 10 | -10 | -100 | -3 | -3 | -1.5 | M4 | 1.2 |
-20N | 20 | -20 | -200 | -6 | -6 | -3 | M4 | 1.2 |
-30N | 30 | -30 | -200 | -9 | -9 | -4.5 | M4 | 1.2 |
-50N | 50 | -50 | -300 | -15 | -15 | -7.5 | M6 | 1.2 |
-100N | 100 | -100 | -500 | -30 | -30 | -15 | M6 | 1.2 |
-200N | 200 | -200 | -800 | -60 | -60 | -30 | M8 | 1.2 |
-300N | 300 | -300 | -1000 | -90 | -90 | -45 | M8 | 2.5 |
-500N | 500 | -500 | -1200 | -150 | -150 | -75 | M8 | 4.5 |