Japan, Ross Asia
Ross Asia LOX® series Electrical isolator
Made in Japan
Manufacturer : Ross Asia
Model : LOX® series
e L-O-X® Electrical Isolation Devices Product Overview
The ROSS e L-O-X ®solution provides for local electrical energy isolation & verification.
The e L-O-X ® includes a Stop button that can be used to send a Stop command to the machine. Once the machine has stopped and the disconnect switch (rotary on 30 to 100 A sizes) has been actuated and locked, isolation may be verified, visually, by use of the 3-phase voltage indicator and, also, by using the Start button to test the machine to verify that it does not run.
The e L-O-X ® electrical isolation device is especially useful in situations where the distance to the main electrical disconnect is excessive and causes extra downtime traveling back and forth between the main disconnect and the machine when performing
Lockout/Tagout.
FEATURES
Specifications
Ordering Information
MODEL NUMBER | Load Rating (Amps) |
E-LOX-030R3A | 30 |
E-LOX-060R3A | 60 |
E-LOX-100R3A | 100 |
E-LOX-200R3A | 200 |
Wiring Diagram | |
E-LOX-030R3A, -060R3A, -100R3A | E-LOX-200F3A |
Operation
The e L-O-X ® is comprised of an enclosure with a load-rated disconnect switch (either rotary or flange-type), a red STOP pushbutton, a green START/TEST pushbutton, and a 3-phase LED power indicator.
The red pushbutton, if utilized, can be used to send a STOP signal to the machine (or zone) controls to stop the machine prior to disconnecting power with the disconnect switch. The STOP switch is a momentary pushbutton- operated NC switch.
The disconnect switch on the e L-O-X ® electrical energy isolation device connects (ON position) and disconnects (OFF position) electrical power to a machine (or machine zone) via a manually operated disconnect switch that is lockable only in the OFF position. Placing the disconnect switch in the OFF position disconnects the electrical power to the machine to isolate the machine from the electrical energy source.
The green START/TEST pushbutton, if utilized, provides a method to send a start signal to the machine (or zone). The START/TEST switch is a momentary pushbutton-operated NO switch. Pressing the green pushbutton after the electrical disconnect switch is placed in the off position and locked-out could also be used to TEST the system to verify electrical power is disconnected and dissipated.
The 3-phase LED power indicator is used to indicate the presence of electrical power on the load side of the disconnect switch (terminals T1, T2, & T3). The power indicator also provides a visual verification of energy release after isolation.
Mounting Information and Overall Dimensions (Inches/mm) | |
E-LOX-030R3A | |
E-LOX-060R3A | |
E-LOX-100R3A | |
E-LOX-200F3A | |