SHOWA SOKKI 7102B Portable Balancer/Field Balancer

Made in Japan
Manufacturer: SHOWA SOKKI
Model: 7102B

Features

  • A strobe type field balancer that can easily measure the balance of a rotating machine.
  • Strobe type field balancer for rotating equipment on site.
  • You can correct a wide range of rotation speeds from 600 to 30,000 rpm.
  • There is an output terminal for monitoring, and waveform observation and recording are possible.
  • A dedicated calculator makes it easy to find the corrected position and corrected weight.
  • It is compact and lightweight, and comes in a convenient carrying case.
  • Carry it to the site for efficient balance correction.
  • We use a strobe method for phase detection, enabling fast and reliable measurements.

Application example

(1) If the mass of the rotating body lacks uniformity with respect to the rotating shaft, resulting in an imbalance, it will exert centrifugal force, which can cause damage to bearings, rotors, holding structures, etc.

(2) There are many causes of unbalanced vibration, such as rotor eccentricity, unevenness, and deflection. In addition, unbalance may occur due to corrosion, wear, deposits, etc. due to aging. In grinders and the like, dressers and grinding cause its imbalance.

(3) A field balancer can correct the balance while the rotor is attached, saving a significant amount of money and time compared to disassembling the machine and using a stationary balancing machine.

(4) The variation in the mass of the rotating body results in one heavy spot (two in the two-plane balance correction method) due to vector synthesis of the imbalance causes. Balancing efficiently involves determining the location and amount of that heavy spot.

Composition

Portable balancer body/7102BOne
Vibration detector/2007One
Same cable 3mOne
stroboscopeOne
shoulder caseOne
operating instructions1 copy

Specification

adaptive detectorModel-2007 Electrodynamic detector 80mV/cm/sec
Measuring range10/30/100/300/1000μmP-P full scale
High sensitivity type is available as an option.
3/10/30/100/300μm P-P full scale (OP)
RPM range600-30,000rpm
filter characteristicsBandpass filter Q=10
300 to 3,000rpm (×1 range)
3,000 to 30,000rpm (×10 range)
monitor output±1 V/full scale (when input resistance is 10 kΩ or more) or
5 mA/full scale (when input resistance is 20 Ω or less)
with output adjuster
stroboscopeHandy type with xenon lamp.
Flash duration 5-10μsec
power supplyAC100V 50/60Hz 30VA
External shape/mass120(H)×240(W)×150(D)mm, about 2.5kg
accessoriesBalance correction calculator (CAL-40) (option)
Sensor fixing magnet (MG-2) (option)

 

REQUEST QUOTATION

PAYMENT

payment-methods

Return Top