Japan, Tokyo Keiso
Tokyo Keiso MASSMAX 6400R Series Coriolis Mass Flowmeter
Made in Japan
Manufacturer: Tokyo Keiso
Model: MASSMAX 6400R
The epoch-making sensing technologies of MASSMAX 6400R series Coriolis flowmeter allow the accurate mass flow measurement in a wide range of temperature from cryogenic service down to -200℃ to high temperature service up to 400℃.
With 9 sizes from 80 to 200 mm, it covers a wide range of flow rates and applications. The Hastelloy® C22 for the wetted parts is also available for corrosive services on request.
Features
- Cryogenic, high temperature and high pressure
- High accuracy: ±0.1% of reading (+ zero stability)
- Instantaneous or totalizing mass flow, density and temperature with one instrument
- Capable of gas measurement also
- Compliant with Japanese standard explosionproof and DNV GL and Lloyd’s ship classifications
Specifications
Measuring principle | Coriolis force |
Fluid | Liquids and gasses (Consult us for gas services) |
Fluid temperature | -50 to +230℃(Standard model) -50 to +400℃(High temperature model) -200 to +40℃(Cryogenic model) -50/-70 to +150℃(Sanitary fitting model) |
Fluid pressure | Max. 10MPa (Sensor tube: Stainless Model steel) Max. 20MPa (Sensor tube: Hastelloy® C22) * Depends on fluid temperature. |
Density | 100 to 3000 kg/m3 |
Measuring range | 5 to 550,000 kg/h |
Meter size | 08, 10, 15, 25, 50, 80, 100, 150, 200 mm |
Process connection | Flange: JIS10K, 20K or equivalent RF, ASME Class 150, 300, 600, 900, 1500 or equivalent RF, etc.Sanitary fitting: ISO 2852 ferrule or others as optional |
Material | Wetted parts
Measuring tube: Stainless steel, Hastelloy® C22, Duplex stainless steel Flange and Flow splitter: Stainless steel, Duplex stainless steel Non-Wetted Part Outer housing: Stainless Steel |
Accuracy (calibrated at the factory) |
Mass flow rate (pulse output)
Liquid: 5% or more of max. flow rate±0.1% of reading Gas: ±0.35% of reading + zero stability |
Enclosure | IP66/67 (IEC 60529) |
Display | Blue dot matrix LCD with backlight |
Output | Current output: 4 to 20 mA (max. 22 mA)
Pulse/Status output: Open collector output |
Power supply | 100 V to 230 V AC (85 V to 253 V AC) Option: 24 V DC (11 to 31 V DC) |
Explosion Proof | Japanese standard explosionproof ATEX explosionproof IECEx explosionproof |
Related Products
-
Line Seiki M13-212 Electronic Counter (Logic Filter)
-
Chiyoda Seiki Fully Automatic Switching Gas Supply Device
-
BIX 3/8-1/2 Square Drive Antivibration Sockets Extension Type
-
Vessel No.GT-P60XW Air Impact Wrench Double Hammer Oil Xtra Series
-
Chino R000, R011, R030, R031 Gas/Air Temperature Sensors
-
Kitz Class 300 Bronze Y-Pattern Swing Check Valve