Japan, Tokyo Keiso
Tokyo Keiso O-1000 Series ORIFLO METER®
Made in Japan
Manufacturer: Tokyo Keiso
Model: O-1000
O-1000is series of Orifice bypass flowmeter. The flow through the main pipe is by -passed by an orifice plate. The bypassed flow is indicated by small sized metal tube variable area flowmeter flow measurement through main pipe.
Features
- Economical measurement even for large size lines.
- Any flow direction of horizontal, vertical including top to bottom possible
- High press. and temp. acceptable thanks to metal tube flowmeter
- No Utility supply needed for local indication.
- Alarm contact(s), Analog output or Totalizers are optionally available
Specifications
Measuring fluid | Liquids(Viscosity: up to 3mPa·s) and Gases (Not suitable for slurry and steam) |
Flow range | Liquids(in case of density: 1.0g/cm³ and viscosity: 1.0mPa·s) Max.600 to 3000m³/h (Size: 500mm, at DP=60kPa) Min.1 to 5m³/h (Size: 50mm, at DP=60kPa)Gases(in case of temperature: 0°C and pressure: 0MPa) Max. 14000 to 70000m³/h(nor) (Size: 500mm, at DP=60kPa) Min. 20 to 100m³/h(nor) (Size: 50mm, at DP= 10kPa) |
Fluid temperature | -20 to 200°C |
Fluid pressure | Max. 1.4MPa (In case of liquid temperature of 120°C or less) Max. 1.2MPa (In case of liquid temperature of more than 120°C to 200°C) |
Type of tapping and available size |
1D·1/2D taps: 100A(4B) to 500A(20B)
Corner (Ring) taps: 50A(2B) to 500A(20B) Flange taps: 50A(2B) to 500A(20B) Vena contrast taps: 100A(4B) to 500A(20B) |
Material | Main orifice: SUS304, SUS316
Orifice ring: SS400, SUS304, SUS316 Ball valve: C3771BE, SCS14A Bypass piping: SGP, SUS304, SUS316 Bypass orifice: SUS304, SUS316 Gasket: Non-Asbestos (for liquids), NBR or FPM (for gases) Flowmeter: SS400/SU304, SUS304 or SUS316 |
Indication accuracy | ±3%F.S. |
Function/ Construction |
O-140□-□□: Local indication / Weather proof IP54 equivalent
O-131□-□□: Local indication + Pneumatic transmission / Weather proof IP54 equivalent O-152□-□□: Local indication + Electric transmission / Weather proof IP54 equivalent EP-O-152□-□□: Local indication + Electric transmission /Flame proof Exd IIBT4 (Ambient temp: -20 to +55°C) O-169□-□□: Local indication + Local integration + Pulse output / Weather proof IP54 equivalent EP-O-169□-□□: Local indication + Local integration + Pulse output / Flame proof d2G4 O-174□-□□: Local indication + Alarm output / Weather proof IP54 equivalent EP-O-174□-□□: Local indication + Alarm output / Flame proof d2G4 IS-O-174□-□□: Local indication + Alarm output / Intrinsically safe Exia IICT6 |