Japan, Zetec
Zetec TOPAZ64 Phased Array Ultrasonic Flaw Detector
Made in Japan
Manufacturer: Zetec
Model: TOPAZ32
Feature:
- 64/128PR Phased Array Ultrasonic Testing Methodology Compliant Inspection
High-definition full matrix capture (FMC)
With up to 1 million data points per frame Total Focusing Method
Time of Flight Diffraction (TOFD) inspection
Applications:
- Weld inspection using live TFM (including austenitic stainless steel and dissimilar metal welds)
- Corrosion inspection using live TFM
- Elementary A-Scan recording using FMC
- Welding inspection (including austenitic stainless steel and dissimilar metal welds)
- Thickness inspection
- Corrosion mapping
- Manual flaw detection (PA, normal UT)
- Automatic flaw detection
- TOFD inspection
- Composite material inspection (time reversal option selectable)
- Special applications for other complex objects.
Product Specifications:
basic specifications | |
---|---|
External dimensions (HxWxD) | 343mm×278mm×158mm |
weight | 9.1 kg (with one battery installed) |
multitap display | 12.1 inches 1024 x 728 pixels |
Outside air intake | No (sealed housing) |
phased array channel | 32/128PR 64/64PR 64/128PR |
Normal UT channel | Pulse Echo x 2 or Pitch & Catch x 2 |
Peak value resolution | 16 bit |
Maximum repetition pulse frequency | 40 kHz |
Maximum pulse voltage | 150Vpp PAUT (bipolar)/75V (unipolar)/200V normal UT |
Bandwidth (-3dB) | 0.5MHz to 18MHz PA 0.5MHz to 25MHz UT |
Maximum number of focal laws | 1024 |
TFM frame size | Up to 1 million points |
TFM frame rate | Up to 110Hz (65,000 point frame resolution) |
encoder | 3 axes (phase difference output) |
software | with UltraVision Touch |
On-board hard drive | 256GB SSD |
Operating environment temperature range | -10°C to 45°C |
Storage temperature range | -40°C to 70°C |
humidity | ~ 80% or less (no condensation) |
Equipment calibration | Conforms to ISO-18563-1/EN12668-1 |
Lineup:
model number | Overview |
---|---|
ZPA-IUTTOPAZ-32/128PR-TFM | A fully integrated portable phased array ultrasound system that can control probes with up to 128 elements and can excite up to 32 elements simultaneously. With this device, 32 transmitting and receiving elements can be used simultaneously in the pulse-echo method, or up to 32 transmitting elements and 32 receiving elements can be driven simultaneously in pitch and catch mode for altitude inspection. Supports bipolar pulser and 256,000 data points onboard FMC/TFM capability. |
ZPA-IUT-TOPAZ- 64/64PR |
A fully integrated portable phased array ultrasound system that can control probes with up to 64 elements and can excite up to 64 elements simultaneously. With this system, 64 transmitting and receiving elements can be used simultaneously in the pulse-echo method, or up to 32 transmitting elements and 32 receiving elements can be individually driven simultaneously in pitch-and-catch mode for advanced inspection. Supports bipolar pulsars. |
ZPA-IUT-TOPAZ- 64/64PR-TFM |
A fully integrated portable phased array ultrasound system that can control probes with up to 64 elements and can excite up to 64 elements simultaneously. With this system, 64 transmitting and receiving elements can be used simultaneously in the pulse-echo method, or up to 32 transmitting elements and 32 receiving elements can be individually driven simultaneously in pitch-and-catch mode for advanced inspection. Supports bipolar pulser and 256,000 data points onboard FMC/TFM capability. |
ZPA-IUT-TOPAZ- 64/128PR |
A fully integrated portable phased array ultrasound system that can control probes with up to 128 elements and can excite up to 64 elements simultaneously. With this system, 64 transmitting and receiving elements can be used simultaneously in the pulse-echo method, or up to 64 transmitting elements and 64 receiving elements can be individually driven simultaneously in pitch-and-catch mode for advanced inspection. Supports bipolar pulsars. |
ZPA-IUT-TOPAZ- 64/128PR-TFM HR |
A fully integrated portable phased array ultrasound system that can control probes with up to 128 elements and can excite up to 64 elements simultaneously. With this system, 64 transmitting and receiving elements can be used simultaneously in the pulse-echo method, or up to 64 transmitting elements and 64 receiving elements can be individually driven simultaneously in pitch-and-catch mode for advanced inspection. Supports bipolar pulser and 1 million data points onboard FMC/TFM capability. |
ZPA-IUT-TOPAZ- 64/128PR-TFM HR-D |
A fully integrated portable phased array ultrasound system that can control probes with up to 128 elements and can excite up to 64 elements simultaneously. With this system, 64 transmitting and receiving elements can be used simultaneously in the pulse-echo method, or up to 64 transmitting elements and 64 receiving elements can be individually driven simultaneously in pitch-and-catch mode for advanced inspection. It supports bipolar pulser and 1 million data points onboard FMC/TFM capability, as well as elementary A-Scan data acquisition capability. |
Related Products
-
Horiuchi LA Tie Rod Type Cylinder K Series
-
Watanabe WSP-HP 1-point setting alarm setter with LCD display – Signal Converter
-
YOSHITAKE GD-200C Pressure Reducing Valve – Water · Oil · Air
-
TSUBOSAN 5-PCS./LENGTH 200mm Round Precision Needle Files
-
TONE CS310 Service Board with Shutter Set
-
Gentos DM Series DM-132B Flashlight (140 lumens)