Tohkemy Beta B Chemical Pump

Manufacturer: Tohkemy Corporation
Model: Beta B

Features

Operation mode
Manual Operation: Offers precise control through dual adjustments—stroke speed (0 to 180 spm) and stroke length (0 to 100%).
Remote Operation: External contact inputs turn the pump on and off remotely.
Pulse Interlocking: Synchronizes pump strokes directly with incoming pulse signals.
Durable & Waterproof Structure
Conforms to IEC standard IP65 for reliable operation in wet environments. An optional outdoor cover provides extra weather protection.
Air Extract Valves
Manual Air Extract Valve: Turning the knob releases trapped air directly from the pump head.
Automatic Air Extract Valve: Automatically purges trapped air from the pump head during operation.
Note: Specific liquid-end designs restrict air valve installation. Please contact us for model compatibility.
High-Viscosity Compatibility (PVT4 Type)
Handles viscous chemicals up to 3,000 mPa·s.
Note: Viscous applications limit total discharge capacity. Please consult our team for exact specifications.

Specifications

Discharge rate:- 533 mL/min
The discharge pressure is rated at – 2.5 MPa
Discharge accuracy:±2% (Conditions recommended by the manufacturer)
Connection: Hose(3×6、4×6、4×9、5×8、6×9、6×11、8×13、9×12 etc.) Piping connection is also possible(15A flange)

Pump sizeAt maximum
pressure
At normal
pressure
Power
consumption
(W)
Connection
Hose diameter
(resin)
mm
Tube
Outer
diameter
(SST)
Reference mass kg
ResinSST
Discharge rateDischarge
pressure
Discharge rateDischarge
pressure
L/Hml/minMPaL/Hml/minMPa
BT4b 10000.7412.31.00.8213.70.57.64×96mm2.53.0
BT4b 16011.118.31.61.423.30.810.04×92.93.6
BT4b 16022.236.71.62.541.70.812.24×92.93.6
BT4b 16043.660.01.64.371.70.816.54×93.13.9
BT4b 07087.1118.30.78.4140.00.3516.56×118mm3.13.9
BT4b 041312.3205.00.414.2236.70.216.56×113.13.9
BT4b 022019.0316.70.220.9348.30.116.58×13.512mm3.34.4
BT5b 10086.8113.31.08.3138.30.520.36×118mm4.55.3
BT5b 071311.0183.30.713.1218.30.3521.26×114.55.3
BT5b 042017.1285.00.419.1318.30.221.28×13.512mm4.75.8
BT5b 25042.948.32.5583.31.021.2No setting6mm5.3
BT5b 023232533.30.236.2603.30.124.98×13.512mm5.16.6

Option
<Relay output>
Alarm relay: Outputs a non-voltage contact signal when an abnormality such as a defective pump body or a low liquid level in a chemical tank occurs.
Pacing relay: Outputs a voltage-free contact signal for each stroke, making it possible to use this signal for synchronized operation of another identical pump or for monitoring the operating status.
<Two-stage level switch>
A level meter installed in a chemical tank. When the liquid level drops to the alarm position, a contact signal is output to the pump and the pump is stopped.
When an alarm relay is attached to the pump, non-voltage contact output linked to the liquid low warning / alarm is possible.

Material

Model namePPEPPBNPENPBPVTTTTSST
Pump
Head
PPAcrylicPVDFPTFESUS316L
Suction valve / Discharge valvePPPVCPVDFPTFESUS316L
O-ringEPDMFPMEPDMFPMPTFE
Valve
Ball
Ceramic
Chemical solution
Example of use
Aluminum sulfate, sodium hydroxide, ferrous sulfate / ferric sulfateHydrochloric acid, dilute sulfuric acid, ferric chloride, PACAluminum sulfate, Sodium hydroxideSodium hypochlorite, sodium thiosulfateHydrochloric acid, sulfuric acid, aqua regia, nitric acidConcentrated sulfuric acid, hydrofluoric acid, mixed acidOrganic solvent, methanol, acetic acid
  • Beta B

REQUEST QUOTATION

PAYMENT

payment-methods

LINK

koueigroup-banner1
koueigroup-banner1

Weight Calculation

Return Top