EIKOH V-700 Series UV-Vis-NIR Spectrophotometer

Made in Japan
Manufacturer: Eikoh Co., Ltd.
Model: V-700 Series: V-730, V-750, V-760, V-770, V-780

The V-700 series UV-Vis-NIR spectrophotometers have been launched as the successor to the highly acclaimed V-600 series. With a diverse lineup of models, we provide users with the highest performance for their measurements and a completely different experience. The V-730 is suitable for routine work, the V-750 and V-760 are high-sensitivity UV-Vis models, and the V-770 and V-780 can measure up to the near-infrared region.

Achieves excellent linearity over a wide wavelength range

We have improved the proven optical system. A wide dynamic range has been achieved by adopting an ultra-high resolution A/D converter and optimizing the optical system and signal processing.

Supports reliable measurements

 Supports Validation

The system offers a validation program. Choosing a standard like JP or USP instantly determines the necessary test items. After starting, simply follow the dialog box instructions to ensure a smooth testing process.
* A separate jig is required.

Daily Inspection Program

A daily program checks the instrument’s condition, included as standard. Each day begins with spectral measurements on filters and other items that remain stable over time. The results are automatically saved, and past measurements can be reviewed chronologically, maintaining data reliability.
* Use the same one every time.

Equipment Diagnostic Function

Every time the device starts, it checks the status of the light source and wavelength drive.

V-700 Series: V-730, V-750, V-760, V-770, V-780

Lamp illumination time display

Control the device via PC or dedicated module

As a tool to control the spectrophotometer, you can choose between a PC or the small module iRM dedicated to device operation.

IQ Accessories (Automatic Accessory Recognition System) & IQ Start

The V-700 series is equipped with IQ accessories, which allow accessories to be automatically recognized by the software and accessory names, serial numbers, etc. automatically recorded in measurement data.

Line up

V-730: A high-performance UV-Vis spectrophotometer with a compact body that can be installed anywhere

  • Measurement wavelength range: 190nm to 1100nm
  • High performance in a compact housing
  • Ideal for liquid measurements
  • Spectral bandwidth 1nm
UV-Visible Spectrophotometer V-730

V-750: Standard UV-Vis model for a wide range of applications

  • Measurement wavelength range: 190nm to 900nm
  • A wide dynamic range is achieved across the entire measurement wavelength range.
  • Highly efficient and bright optical system with single monochromator
  • By attaching various accessories, it can be used in a wide range of applications.
UV-Visible Spectrophotometer V-750

V-760: Extremely low stray light model equipped with a double monochromator

  • Measurement wavelength range: 187nm to 900nm
  • Achieves Abs6 across a wide range of wavelengths
  • Double monochromator adopted to achieve class-leading extremely low stray light (0.00008%)
UV-Visible Spectrophotometer V-760

V-770: Covers a wide range of wavelengths from UV to visible to near infrared

  • Measurement wavelength range: 190nm to 2700nm (optionally expandable to 3200nm)
  • Highly efficient and bright optical system with a single monochromator
UV-Vis-NIR Spectrophotometer V-770

V-780: High-sensitivity, high-resolution measurement model for UV, visible, and near-infrared regions equipped with an InGaAs detector

  • Measurement wavelength range: 190nm to 1600nm
  • High sensitivity, high resolution model using InGaAs detector in near infrared region
  • New lamp house improves stability in the near infrared range

Specification

V-730/750/760

Model name
V-730 V-750 V-760
Optical system Rowland outer circular arrangement single monochromator double beam system Czerny-Turner mount , single monochromator, double beam system Czerny-Turner configuration, dual monochromator, twin beam setup
light source

Deuterium lamp, halogen lamp

Wavelength range

190-1100nm

190-900nm 187-900nm
Wavelength Accuracy ±0.2nm (656.1nm)

±0.1nm (656.1nm)

Spectral Bandwidth (SBW)

1 nm

0.1, 0.2, 0.5, 1, 2, 5, 10nm
L2, L5, L10nm (low stray light mode)
M1, M2nm (microcell mode)

Stray light

1% (198nm KCl, 12g/L in water)
With 0.02% (220nm NaI, 10g/L in water)
Containing 0.02% (340nm NaNO2, 50g/L in water)
At 0.02% (370nm NaNO2, 50g/L in water)
SBW 1nm

1% (198nm KCl, 12g/L in aqueous solution)
At 0.005% (220nm NaI, 10g/L in aqueous solution)
Containing 0.005% (340nm NaNO2, 50g/L in aqueous solution)
With 0.005% (370nm NaNO2, 50g/L in aqueous solution)
SBW L2nm

1% (198nm KCl, 12g/L in aqueous solution)
At 0.00008% (220nm NaI, 10g/L in aqueous solution)
Containing 0.00008% (340nm NaNO2, 50g/L in aqueous solution)
With 0.00008% (370nm NaNO2, 50g/L in aqueous solution)
SBW L2nm

Photometric Accuracy

±0.0015Abs (0-0.5Abs)
±0.0025Abs (0.5-1Abs)
±0.3%T at NIST SRM 930

Detector

Silicon photodiode

Photomultiplier tube

Standard Program Abs/%T meter, quantitative measurement, spectrum measurement, time change measurement, fixed wavelength measurement, validation, daily inspection, macro command (iRM only), 2 wavelength time change measurement (DS only)
display

Japanese/English (iRM), Japanese (DS)

Dimensions & Weight

486(W) x 441(D) x 216(H)mm, 15kg

460(W) x 602(D) x 268(H)mm, 27kg

460(W) x 602(D) x 268(H)mm, 29kg

V-770/780

Model name
V-770 V-780
Optical system Czerny-Turner mount, single monochromator, double beam system
light source Deuterium lamp, halogen lamp
Wavelength range 190-2700nm (3200nm * ) 190-1600nm
Wavelength Accuracy ±0.3nm (656.1nm)
±1.5nm (1312.2nm)
±0.3nm (656.1nm)
±1.0nm (1312.2nm)
Spectral Bandwidth (SBW)

0.1, 0.2, 0.5, 1, 2, 5, 10nm
L2, L5, L10nm (low stray light mode)
M1, M2nm (microcell mode)
(UV-Vis)0.4, 0.8, 1, 2, 4, 8, 20, 40nm
L8, L20, L40nm (low stray light mode)
M4, M8nm (microcell
(near infrared)

0.1, 0.2, 0.5, 1, 2, 5, 10nm
L2, L5, L10nm (low stray light mode)
M1, M2nm (microcell mode)
(UV-Vis)0.2, 0.4, 0.5, 1, 2, 4, 10, 20nmL4, L10, L20nm (low stray light mode)
M2, M4nm (microcell mode)
(near infrared)
Stray light 1% (198nm KCl, 12g/L in aqueous solution)
At 0.005% (220nm NaI, 10g/L in aqueous solution)
Containing 0.005% (340nm NaNO2, 50g/L in aqueous solution)
With 0.005% (370nm NaNO2, 52g/L in aqueous solution)
SBW L2nm
Including 0.04% (1420nm: H2O)
Also 0.1% (1690nm: CH2Br2, 50mm cell) SBW L8nm

1% (198nm KCl, 12g/L in aqueous solution)
At 0.005% (220nm NaI, 10g/L in aqueous solution)
Containing 0.005% (340nm NaNO2, 50g/L in aqueous solution)
With 0.005% (370nm NaNO2, 52g/L in aqueous solution)
SBW L2nm
Including 0.04% (1420nm: H2O) SBW L4nm

Photometric Accuracy

±0.0015Abs (0-0.5Abs)
±0.0025Abs (0.5-1Abs)
±0.3%T at NIST SRM 930

Detector Photomultiplier tube, cooled PbS photoconductive element Photomultiplier tubes, cooled InGaAs photodiodes
Standard Program Abs/%T meter, quantitative measurement, spectrum measurement, time change measurement, fixed wavelength measurement, validation, daily inspection, macro command (iRM only), 2 wavelength time change measurement (DS only)
display Japanese/English (iRM), Japanese (DS)
Dimensions & Weight 460(W) x 602(D) x 268(H)mm, 29kg

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top