Japan, Kyowa Electronic Instruments Co., Ltd.
Kyowa EDX-13A Thermocouple Measurement Unit EDX-10 Series Compact Recording System
Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model:EDX-13A Thermocouple Measurement Unit
- Compact and lightweight
Stack connection eliminates the need for synchronous cables and saves wiring - Simultaneous sampling of 1 channel at up to 20kHz is possible with a single measurement unit
- An input cable or input adapter makes it easy to connect sensors.
Feature
An instrument that can be measured with a USB interface. Strain, voltage and temperature (thermocouple) can be measured. Up to 4 units and 16 channels can be powered by USB bus power, eliminating the need for a separate power supply.
Specification
Measurement object | thermocouple |
---|---|
Number of input channels | 4 |
Input connector | Screw connection terminal block |
Compatible thermocouples | K,T,J,N *Thermocouple resistance 1 kΩ or less |
Measuring range, resolution, measurement accuracy, internal reference junction compensation accuracy | Type: K Measurement range: -200.0~1370.0°C Resolution: 0.1°C Measurement accuracy: -200.0~-100.0°C: ±(0.2%+0.6°C of the indicated value) -100.0~1370.0°C: ± (0.1%+0.4°Cof the indicated value)Type: T Measurement range: -200.0~400.0°C Resolution: 0.1°C Measurement accuracy: -200.0~-100.0°C: ±(0.2%+0.6°C of the indicated value) -100.0~400.0°C: ± (0.1%+0.4°C of the indicated value) Type: J ) Type: N : ±( 0.1% of the indicated value + 0.4°C) Accuracy of internal reference contact guaranteer: ±1.0°C [Input terminal temperature at equilibrium] [Ambient temperature range 25±10°C] * When combined with a measurement unit other than EDX-13A, the EDX-13A is mounted on the lower side. |
Measuring range | K: T: J: N: |
Check function | Burnout check |
AD converter resolution | 24-bit |
Sampling method | scanning |
Internal sampling frequency | Approx. 0.5Hz, Approx. 2.0Hz |
Operating temperature and humidity range | 0~40°C,20~90%(non-condensing) |
power | Supplied by DC 5V control unit |
Current consumption | 120mA or less (at 5V power supply) |
mass | Approx. 130g |
External dimensions | 84.0(W)×26.6(H)×84.0(D)mm(excluding protrusions) |
Conformity directives | EMC Directive 2014/30/EU RoHS Directive 2011/65/EU (6 substances) |
* Measurement accuracy does not include the accuracy of the internal reference junction compensator and the accuracy of the thermocouple. The measurement error during internal reference junction compensation is the sum of the error due to measurement accuracy, the error of the internal reference junction compensator, and the error of the thermocouple. * Measurement conditions for accuracy ± 1.0°C of the internal reference contact compensator Condition 1: When combined with a measurement unit other than the EDX-13A, the EDX-13A is mounted on the lower side. |
Standard Accessories | 1 terminal block1 screwdriver |
---|