Kyowa EDX-200A-1 Max 8 channels, 1 slot EDX-200A Universal Recorder

Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model: EDX-200A-1 Max 8 channels, 1 slot

  • Equipped with a real-time digital filter 8th order digital filter can acquire beautiful waveforms.
    High-speed/low-speed dual sampling Fast and slow phenomena can be measured with a reduced amount of data.
    A high-speed sampling of all channels at 10kHz simultaneously (at 32 channels)Simultaneous measurement of 100 channels at up to 3kHz is possible
    Can be used in high and low-temperature environments (EDX-200A-4T only) Supports -20°C~65°C
  • One-wire synchronization (other than EDX-200A-1)
    Up to 8 units, can be used for large-scale measurement with distributed arrangement.

Feature

A compact and high-end EDX that supports a wide variety of measurements with a wide selection of conditioner cards while maintaining the convenience of the EDX-100A.

Specification

Model Name EDX-200A-1 (w/DCS-100A)
EDX-200A-1-1 (w/DCS-100A, DCS-101A)
Measurement object Strain (gauge, transducer), voltage, thermocouple, pulse (F/V), piezoelectric acceleration (built-in amplifier), CAN signal
Analog Input EDX Series Conditioner Card Strain/Voltage/Acceleration Measurement Card CVM-41A
Strain/Voltage Measurement Card CDV-40B/40B-F Dynamic Strain Measurement Card
DPM-42B DPM-42B-FDPM-42B-I

DPM-42B-I-F Thermocouple Card CTA-40A F/V Converter Card CFV-40A Charge Amplifier Card CCA-40A/40A-F

CAN Card CAN-41A

strain/voltage measurement isolation card CDV-44AS/46AS
DC constant current amplification card (120 Ω) CDA-44AS DC constant current amplification card (350 Ω) CDA-45AS

AD converter card AD-40AS/40AS-F

[Note] The CFV-40A has mounting limitations.
Up to 1 sheet

CAN data input CAN card (2 ports, maximum 256 channels): CAN-41A(*) CAN-41A
can be mounted in the final slot
Voice memo input 1-channel (input voice memos can be recorded together with measurement data) Remote control unit RCU-42A (sold separately) Data
playback software DAS-200A (sold separately)
is used to play back recorded voice memos.
sampling
Sampling method All channels simultaneously
Sampling Mode Normal: Acquire
all channels at the same sampling frequency
Dual: Acquire two different sampling frequencies per channel:fast or slow
sampling frequency In
normal sampling mode [1/2/5 series]
1Hz~100kHz
1Hz~2kHz : When
CAN-41A data is measured [2nSeries】
2Hz~65536Hz
2Hz~2048Hz :CAN-41A High-speed sampling (Sf)
in
dual sampling mode duringdata measurement [1/2/5 series]
1Hz~100kHz
1Hz~2kHz : CAN-41A data
measurement [2

nSeries: 2Hz~65536Hz 2Hz~2048Hz :
Low-speed sampling (Ss)
duringCAN-41A data measurement [1/2/5 series]
1/2/5 series division of high-speed sampling, except that Ss ≦Sf/4
[
2

nSeries】
2 of high-speed samplingnDivide the series, but Ss≦Sf/4

Measurable number of channels 320000 in normal sampling mode / integer part of “set sampling frequency”, except 32 in

320000-channel

dual sampling mode / integer part of “set sampling frequency”, but up to 64 channels
* “high speed + low speedAbout
the setting channel The number of channels per channel is 1 channels

for CAN data at the time
of CAN-2A data measurement.

Programmable sampling frequency The high-speed sampling frequency in
dual sampling mode below(320000/”number of channels”) is (320000/”number of channels”) or less
* About
the “high-speed + low-speed” setting channelTwo channels of acquired data per channel
Digital Filters Butterworth Filter (IIR) Filter Type: Low-pass Filter, High-Pass Filter
Order: Number of Amplitudes at 1~8th Cutoff
Point: -3dB Attenuation Characteristics: -6dB
×N dB/oct. (N is the order of the filter)* Can be
used with a low-pass filter with a conditioner card Digital filter of CAN data cannot be applied
Data storage CF Card Capacity : 128M~16GB (recommended by our company) Maximum data file size (data file size that can be acquired)

When the number of measurement repetitions is 1 time 4GB/1 data file When the number of measurement repetitions is 2 or more times 1GB/1 data file

( 1GB=1000000000 bytes)

Indicator Channel status display LEDs: 8 LEDs
Main unit status display LEDs: 4 pcs
Operation switch REC/PAUSE:Start Acquisition/Stop
AcquisitionSTOP:Stop AcquisitionBAL
.: Balance (Balance
Adjustment)LOAD:Read and Set Conditions from CF CardOPT.:Execute
Optional Functions SetPOWER
:Power SwitchUSB
/ LAN: Communication I/F switching
External Control Connector CONT. IN (for remote control)
Communication Interface USB (USB2.0 High Speed) 1-Port Connector Shape : Series B Receptacle
LAN (10/100BASE-T)2-Port

LAN IN : PC Communication
Connector Shape : RJ45 Modular Jack

Synchronous operation incompatible
How to set conditions Online setting: Set on PC via LAN or USB interfaceOffline setting:

Set

by reading the setting conditions in the CF card into the instrument (DCS-100A is used to create measurement conditions)

Saving Conditions Conditioner setting conditions and measurement conditions can be stored in
EDX’s built-in nonvolatile memory, and data can be acquired immediately under the previous measurement conditions.
Measurement mode
Manual measurement/trigger measurement/interval measurement
Manual measurement It is possible to start and stop data acquisition by user operation, or stop
acquisition with a set number of data, and record voice memos at the time of this measurement.
Trigger measurement Automatic acquisition function
(Note) Triggering with CAN data acquired by CAN-41A is not possible under preset trigger conditions.
Interval measurement Combination of Measurement Modes in Dual Sampling Mode for Automatic Acquisition Function Under

Predetermined Interval Conditions:
High-Speed Sampling Channel— Manual Setting
——– Low-Speed Sampling Channel
Trigger settings———- manual settings, interval settings
——– interval settings

Start/Stop Acquisition Executed by PC, operation switch (panel surface), dedicated remote control
Balance adjustment operation (balance operation) Strain input channel balance adjustment is performed by a personal computer, operation switch (panel surface), or dedicated remote control.
Acquired Data Format Analysis is possible using the DAS-2A data analysis software sold separately in the KS200
Republican standard format.
Data recovery Online collection by PC or offline collection by reading CF card directly into PC
TEDS function [Compatible conditioner cards]
CDV-40B(-F), DPM-42B(-F),DPM-42B-I(-F),CCA-40A(-F),CDV-44AS,CDA-44AS, CDA-45AS,CVM-41A
power DC 10~33V
connector type : RM12BRD-4PH (Hirose Electric)
DC power supply or AC adapter (sold separately)
Current consumption Approx. 1.0A (DC 12V, 40 CDV-1B mounted)
Operating temperature range 0~50℃
Operating humidity range 20~90%(non-condensing)
Storage temperature range -20~60℃
Vibration resistance 49.0m/s2 (5G), 5~55Hz 1 cycle 1 minute, 15 cycles per axis (non-operating)
29.4m/s2 (3G), 5~55Hz 1 cycle 1 minute, 15 cycles per axis (operating)
Impact resistance 294.2m/s2(30G)/11ms
External dimensions 148(W)×53(H)×257(D)mm not including protrusions
mass Main unit: Approx. 0.9kg (Approx. 40.1kg when one CDV-1B is mounted)
Conformity directives EMC Directive 2014/30/EU RoHS Directive 2011/65/EU,(EU
) 2015/863(10 substances)
Standard Accessories DC Power Cable P-76
USB Cable N-38
Ground Wire P-72
Mounted
in CF Card (1GB) SlotEDX AccessoriesBagDynamic
Data Acquisition Software DCS-100A(DVD)
*The model name ends with “- If it is “0”, DCS-100A will be sold separately.
Instruction manual (Japanese/English, DVD)
Sold separately AC Adapter UIA200-345 for EDX-12A
(UNI345-1238 for the U.S.)
Fixed Adapter
EDX Dummy Panel EDX1P-DUMMY
Remote Control Unit RCU-42A Monitor Unit EMON-20A

Dimensions

EDX-200A-1

Remarks

EDX-200A-2H/4H: CE compatible products can also be manufactured. Please contact us.

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top