Products Made in Japan
Manufacturer :SENSEZ
Model :TKB-TS.TKB-HR-LV.TKB-HR-24.TKB-MA
Features
- This box has a plastic waterproof casing (IP66) and, when connected to an immersion-type water level meter, serves as a relay between the measuring and control devices of the control panel. Three types are available: terminal block connection, built-in arrester, and 4-20 mA meter display.
- The casing has a silica gel container built in it for dew condensation prevention.
- The waterproof casing has a vent filter for atmospheric relief, which enables atmospheric relief of the water level meter.
- Cabling can be performed easily using waterproof cable glands.
Characteristics
- This box has a plastic waterproof casing (IP66) and, when connected to an immersion-type water level meter, serves as a relay between the measuring and control devices of the control panel.
- Three types are available: terminal block connection, built-in arrester, and 4-20 mA meter display.
- The casing has a silica gel container built in it for dew condensation prevention.
- The waterproof casing has a vent filter for atmospheric relief, which enables atmospheric relief of the water level meter.
- Cabling can be performed easily using waterproof cable glands.
Specifications
- <Terminal block specifications> ●Model:TKB-TS
- <Arrester specifications(Voltage type)> ●Model:TKB-HR-LV
- <Arrester specifications(Current type)> ●Model:TKB-HR-24
- <Indicator specifications> ●Model:TKB-MA
Terminal block specifications
Model |
TKB-TS |
Operating temperature range |
20 to 60°C |
Outer diameter of the cable used |
$ 4 to 8 |
Number of cables connected |
4 (4 pairs) |
Connection method |
Screw terminal block (M3×8L) |
Casing |
Waterproof (IP66) Material: Polycarbonate + ABS resin |
External dimension / Weight |
82 (W) × 162 (H) × 55 (D) mm Approx. 380g |
Cable gland |
2 waterproof glands (IP68) Main unit material: Polyamide |
Vent filter |
Main unit material: Polyamide Filter: PTFE |
Terminal block specifications |
Ratings: 250V 15A Insulation resistance: 500 VDC 200 MQ or more |
Arrester specifications
Model |
Voltage type: TKB-HR-LV Current type: TKB-HR-24 |
Operating temperature range |
5 to 55°C |
Outer diameter of the cable used |
4 to 8 |
Connection method |
Screw terminal block (M3×8L) |
Casing |
Waterproof (IP66) Material: Polycarbonate + ABS resin |
External dimension / Weight |
127 (W) × 175 (H) × 100 (D) mm Approx. 850g |
Cable gland |
2 waterproof glands (IP68) Main unit material: Polyamide |
Vent filter |
Main unit material: Polyamide Filter: PTFE |
Arrester specifications |
< Voltage type> Arrester model:: MDK-LV Maximum operating voltage: 30V Voltage protection level: 40V Response time: 0.1 με Discharge capacity: 5000A (8/20 μ s) Maximum load current: 100mA
< Current type> Arrester model: MDK-24 Maximum operating voltage: 30V Voltage protection level: 40V or less Response time: 0.1 µs Discharge capacity: 5000A (8/20 μs) Maximum load current: 100mA |
Indicator specifications
Model |
TKB-MA |
Operating temperature range |
10 to 45°C |
Outer diameter of the cable used |
$ 4 to 8 |
Number of cables connected |
4 (4 pairs) |
Connection method |
Screw terminal block (M3×8L) |
Casing |
Waterproof (IP66) Material: Polycarbonate + ABS resin |
External dimension / Weight |
127 (W) x 175 (H) x 100 (D) mm Approx. 700g |
Cable gland |
2 waterproof glands (IP68) Main unit material: Polyamide |
Vent filter |
Main unit material: Polyamide Filter: PTFE |
Terminal block specifications |
Ratings: 600V 30A Insulation resistance: 500 VDC 1000MQ or more |
Indicator specifications |
Scale: 0 to 20 mA Minimum scale value: mA Class: 2.5 Panel dimensions: 50 x 50 mm |
Dimensions(Units:mm)