Features
-
- Easy to handle because of the dial gage system employed (Graduation: 0.01mm).
- Less variation with lapse of time because of the cantilever system employed.
- Excellent thermal characteristics because of the compensation circuit inserted into the system.
- Can make calibration simply by utilizing graduations on the dial gage (Note that the dial graduations show calibration reference values only).
- Accuracy class: 0.5% RO.
Appearance Dimensions
Model and Capacity / Dimension / etc. (unit : mm)
Model | Capacity | A | B | C | D | E | F | G | H | J | K | L | M | Reaction force(N):start point/end point | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TCL-5FA | 5 mm | 106.5 | 65 | 41.5 | 52.8 | 49 | 14.1 | 14.5 | 11.5 | 25 | 20.5 | 8 | 11 | 0.5/1.6 | 155 g |
TCL-10FA | 10 mm | 106.5 | 65 | 41.5 | 52.8 | 49 | 14.1 | 14.5 | 11.5 | 25 | 20.5 | 8 | 11 | 0.5/1.8 | 155 g |
TCL-20FA | 20 mm | 129.5 | 88.5 | 41 | 66.5 | 62.5 | 20 | 14.5 | 12 | 24 | 27 | 8 | 10.5 | 0.6/2.0 | 170 g |
TCL-30FA | 30 mm | 146.5 | 100.5 | 46 | 77.5 | 72.5 | 17.3 | 17.5 | 11 | 24 | 24.3 | 8 | 11 | 0.6/2.2 | 220 g |
* The weight indicated in the tables of this data sheet does not include the weight of cables.
Specifications
Rated Output | 1.5 mV/V±1 % |
---|---|
Nonlinearity | 0.5 %R.O. |
Hysteresis | 0.5 %R.O. |
Repeatability | 0.3 %R.O. |
Excitation Voltage | 3 V (or less) |
Safe Excitation Voltage | 4 V |
Input Rsistance | 350 Ω |
Output Rsistance | 350 Ω |
Compensated Temp.Range | 5~40 ℃ |
Safe Temp.Range | 5~50 ℃ |
Temp.Effect on Zero | 0.02 %R.O./℃ |
Temp.Effect on Output | 0.02 %/℃ |
Cable | Φ4mm-4wire shielded cable, length : 0.3m |
Attached connector | Jack /PRC03-32A10-7F |