Features
Supports a wide range of capacities from small to large (power: 0.1 to 30 kW)
Covers a large number of reduction ratios and easy to select the optimum rotation speed
Ideal for floc formation, sedimentation prevention, agitation of viscous liquid
Standard specifications
Cyclo reducer, 0.1-2.2kW
Model No. | Power | Rotation speed (min-1) | 2-Blade pitched paddle | Shaft (mm) | Maximum agitating capacity (m3) |
|---|
Output (kW) | Number of poles (P) | 50Hz | 60Hz | Paddle diameter φD | Shaft diameter φd | Standard length L | Dilute liquid | Medium viscosity liquid |
|---|
| NTC4-001-15 | 0.1 | 4 | 96.7 | 117 | 300 | 20 | 1,200 | 0.7 | 0.24 |
| -21 | 69.0 | 83.3 | 350 | 1,500 |
| -25 | 58.0 | 70.0 | 400 | 0.9 | 0.32 |
| -29 | 50.0 | 60.3 | 450 |
| -35 | 41.4 | 50.0 | 550 | 1.2 | 0.4 |
| -43 | 33.7 | 40.7 | 600 |
| -59 | 24.6 | 29.7 | 800 |
| NTC4-002-15 | 0.2 | 4 | 96.7 | 117 | 350 | 20 | 1,200 | 1.3 | 0.44 |
| -21 | 69.0 | 83.3 | 450 | 1,300 |
| -25 | 58.0 | 70.0 | 500 | 1,400 | 1.4 | 0.46 |
| -29 | 50.0 | 60.3 | 550 | 1,500 |
| -35 | 41.4 | 50.0 | 600 | 1.8 | 0.64 |
| -43 | 33.7 | 40.7 | 700 |
| -59 | 24.6 | 29.7 | 850 | 25 |
| NTC4-004-15 | 0.4 | 4 | 96.7 | 117 | 400 | 25 | 1,300 | 2.4 | 0.8 |
| -21 | 69.0 | 83.3 | 500 | 1,500 |
| -25 | 58.0 | 70.0 | 550 | 2.8 | 0.96 |
| -29 | 50.0 | 60.3 | 650 |
| -35 | 41.4 | 50.0 | 750 | 30 | 1,800 | 3.8 | 1.2 |
| -43 | 33.7 | 40.7 | 800 |
| -59 | 24.6 | 29.7 | 1,000 |
Model No. | Power | Rotation speed (min-1) | 2-Blade pitched paddle | Shaft (mm) | Maximum agitating capacity (m3) |
|---|
Output (kW) | Number of poles (P) | 50Hz | 60Hz | Paddle diameter φD | Shaft diameter φd | Standard length L | Dilute liquid | Medium viscosity liquid |
|---|
| NTC4-007-15 | 0.75 | 4 | 96.7 | 117 | 450 | 30 | 1,500 | 4.5 | 1.5 |
| -21 | 69.0 | 83.3 | 600 | 1,800 |
| -25 | 58.0 | 70.0 | 650 | 5.4 | 1.8 |
| -29 | 50.0 | 60.3 | 750 |
| -35 | 41.4 | 50.0 | 800 | 7 | 2.4 |
| -43 | 33.7 | 40.7 | 900 |
| -59 | 24.6 | 29.7 | 1,150 | 40 | 2,000 |
| NTC4-015-15 | 1.5 | 4 | 96.7 | 117 | 550 | 40 | 1,800 | 8.5 | 3 |
| -21 | 69.0 | 83.3 | 700 |
| -25 | 58.0 | 70.0 | 750 | 10 | 3.6 |
| -29 | 50.0 | 60.3 | 850 |
| -35 | 41.4 | 50.0 | 950 | 13 | 4.8 |
| -43 | 33.7 | 40.7 | 1,050 |
| -59 | 24.6 | 29.7 | 1,350 | 45 | 2,200 |
| NTC4-022-15 | 2.2 | 4 | 96.7 | 117 | 600 | 40 | 1,800 | 14 | 5.5 |
| -21 | 69.0 | 83.3 | 750 | 2,000 |
| -25 | 58.0 | 70.0 | 850 | 15 | 6 |
| -29 | 50.0 | 60.3 | 950 | 45 | 2,200 |
| -35 | 41.4 | 50.0 | 1,050 | 20 | 8 |
| -43 | 33.7 | 40.7 | 1,200 | 50 | 2,500 |
| -59 | 24.6 | 29.7 | 1,450 |
Reduction ratios (one step) that can be selected other than this table include 1/6, 1/8, 1/11, 1/13, 1/17, 1/51, 1/71, and 1/87.
The standard motor is a fully enclosed fan made by Sumitomo outdoors.
The standard blade is a 2-pitch paddle and the number of stages is 2, but the blade shape may change depending on the purpose and specifications.
If the stirring shaft is Φ50 mm or more, flange coupling is used as standard.
If the blade diameter is Φ1100mm or more, the separate method is standard.
Please contact us for non-standard specifications.
Dilute liquids have a viscosity of about 0.1 Pa · s (100 cp), and medium-viscosity liquids have a viscosity of about 0.1-0.5 Pa · s (100-500 cp).
Cyclo reducer, 3.7-30kW
Model No. | Power | Rotation speed (min-1) | 2-Blade pitched paddle | Shaft (mm) | Maximum agitating capacity (m3) |
|---|
Output (kW) | Number of poles (P) | 50Hz | 60Hz | Paddle diameter φD | Shaft diameter φd | Standard length L | Dilute liquid | Medium viscosity liquid |
|---|
| NTC4-037 -15 | 3.7 | 4 | 96.7 | 117 | 700 | 45 | 2,000 | 22 | 8.5 |
| -21 | 69.0 | 83.3 | 850 | 2,200 |
| -25 | 58.0 | 70.0 | 950 | 50 | 2,500 | 25 | 9 |
| -29 | 50.0 | 60.3 | 1,050 |
| -35 | 41.4 | 50.0 | 1,200 | 30 | 12 |
| -43 | 33.7 | 40.7 | 1,350 | 60 |
| -59 | 24.6 | 29.7 | 1,650 | 70 | |
| NTC4-055 -15 | 5.5 | 4 | 96.7 | 117 | 750 | 50 | 2,200 | 33 | 13 |
| -21 | 69.0 | 83.3 | 900 | 60 | 2,500 |
| -25 | 58.0 | 70.0 | 1,050 | 36 | 14 |
| -29 | 50.0 | 60.3 | 1,150 |
| -35 | 41.4 | 50.0 | 1,300 | 70 | 48 | 19 |
| -43 | 33.7 | 40.7 | 1,450 |
| -59 | 24.6 | 29.7 | 1,750 | 80 | 2,700 |
| NTC4-075 -15 | 7.5 | 4 | 96.7 | 117 | 800 | 60 | 2,400 | 45 | 16 |
| -21 | 69.0 | 83.3 | 1,000 | 70 | 2,500 |
| -25 | 58.0 | 70.0 | 1,100 | 54 | 19 |
| -29 | 50.0 | 60.3 | 1,250 |
| -35 | 41.4 | 50.0 | 1,400 | 70 | 25 |
| -43 | 33.7 | 40.7 | 1,550 | 80 |
| -59 | 24.6 | 29.7 | 1,900 | 2,800 |
| NTC4-110 -15 | 11 | 4 | 96.7 | 117 | 850 | 70 | 2,500 | 65 | 22 |
| -21 | 69.0 | 83.3 | 1,100 |
| -25 | 58.0 | 70.0 | 1,250 | 80 | 80 | 26 |
| -29 | 50.0 | 60.3 | 1,350 |
| -35 | 41.4 | 50.0 | 1,500 | 2,800 | 100 | 35 |
| -43 | 33.7 | 40.7 | 1,650 | 90 |
| -59 | 24.6 | 29.7 | 2,000 | 3,000 |
Model No. | Power | Rotation speed (min-1) | 2-Blade pitched paddle | Shaft (mm) | Maximum agitating capacity (m3) |
|---|
Output (kW) | Number of poles (P) | 50Hz | 60Hz | Paddle diameter φD | Shaft diameter φd | Standard length L | Dilute liquid | Medium viscosity liquid |
|---|
| NTC4-150 -15 | 15 | 4 | 96.7 | 117 | 900 | 70 | 2,500 | 90 | 30 |
| -21 | 69.0 | 83.3 | 1,150 | 80 | 2,800 |
| -25 | 58.0 | 70.0 | 1,300 | 110 | 36 |
| -29 | 50.0 | 60.3 | 1,400 | 90 |
| -35 | 41.4 | 50.0 | 1,600 | 3,000 | 140 | 45 |
| -43 | 33.7 | 40.7 | 1,750 |
| -59 | 24.6 | 29.7 | 2,200 | 100 | 3,200 |
| NTC4-185 -15 | 18.5 | 4 | 96.7 | 117 | 950 | 80 | 2,700 | 115 | 38 |
| -21 | 69.0 | 83.3 | 1,200 | 90 | 2,800 |
| -25 | 58.0 | 70.0 | 1,350 | 140 | 45 |
| -29 | 50.0 | 60.3 | 1,450 | 3,000 |
| -35 | 41.4 | 50.0 | 1,650 | 180 | 60 |
| -43 | 33.7 | 40.7 | 1,850 | 100 | 3,200 |
| -59 | 24.6 | 29.7 | 2,300 | 110 | 3,500 |
| NTC4-220 -15 | 22 | 4 | 96.7 | 117 | 1,000 | 80 | 2,700 | 140 | 50 |
| -21 | 69.0 | 83.3 | 1,250 | 90 | 2,800 |
| -25 | 58.0 | 70.0 | 1,400 | 3,000 | 160 | 60 |
| -29 | 50.0 | 60.3 | 1,500 | 100 | 3,200 |
| -35 | 41.4 | 50.0 | 1,750 | 220 | 80 |
| -43 | 33.7 | 40.7 | 1,950 | 110 | 3,500 |
| -59 | 24.6 | 29.7 | 2,400 | 120 | 3,800 |
| NTC4-300 -15 | 30 | 4 | 96.7 | 117 | 1,100 | 90 | 2,900 | 180 | 65 |
| -21 | 69.0 | 83.3 | 1,350 | 3,000 |
| -25 | 58.0 | 70.0 | 1,450 | 100 | 3,200 | 210 | 75 |
| -29 | 50.0 | 60.3 | 1,600 |
| -43 | 33.7 | 40.7 | 2,100 | 120 | 3,500 | 280 | 100 |
| -59 | 24.6 | 29.7 | 2,450 | 3,800 |
Reduction ratios (one step) that can be selected other than this table include 1/6, 1/8, 1/11, 1/13, 1/17, 1/51, 1/71, and 1/87.
The standard motor is a fully enclosed fan made by Sumitomo outdoors.
The standard blade is a 2-pitch paddle and the number of stages is 2, but the blade shape may change depending on the purpose and specifications.
If the stirring shaft is Φ50 mm or more, flange coupling is used as standard.
If the blade diameter is Φ1100mm or more, the separate method is standard.
Please contact us for non-standard specifications.
Dilute liquids have a viscosity of about 0.1 Pa · s (100 cp), and medium-viscosity liquids have a viscosity of about 0.1-0.5 Pa · s (100-500 cp).
Mounting flange dimensions(mm)
| Similary JIS 10K | Outer diameter OD | Pitch PCD | Number of mounting bolts x hole diameter n×φh | Flange thickness T |
|---|
| 125A | 250 | 210 | 4-φ19 | 17 |
| 150A | 280 | 240 | 4-φ23 | 22 |
| 200A | 330 | 290 | 6-φ23 | 22 |
| 250A | 400 | 355 | 6-φ25 | 24 |
| 300A | 445 | 400 | 8-φ25 | 26 |
| 400A | 560 | 510 | 8-φ27 | 32 |
| 450A | 620 | 565 | 10-φ27 | 32 |
Common specification items
| Motor | 3-phase 200V 50Hz, 200/220V 60Hz 0.1kW: Totally-enclosed non-ventilated, 0.2kW ~: Totally-enclosed fan-cooled |
|---|
| Standard accessories | Simple tools (excluding large models), instruction manual |
|---|
| Painting | Munsell 2.5G6 / 3 (motor : manufacturer’s standard color) |
|---|
* Different voltages such as 380/400/440V are also available.