Tokyo Keiso MA-900 Micro Flowmeter
Made in Japan
Manufacturer: Tokyo Keiso
Model: MA-900
MA-900 is a metal tube variable area flowmeter designed for the measurement of small flow of liquids and gases. MA-900 covers tough applications with high pressure and temperature which are not suitable for glass tube purge meters. In addition to local indication version, an alarm output option is available.
Features
- Very small flow rate can be covered
Min. 0 – 0.5 L/h [Water] can be measured.
- Alarm output option available
In addition to local indication type, alarm output version is also available.
- Compact design
Easy installation onto instrument panel
- Safety for high temperature and pressure
All metallic material construction covers tough applications!
Specifications
Model and function | MA-90X: Local indication only MA-95X: Local indication + Alarm output |
---|---|
Measuring fluid | Liquids, Gases (Not suitable for slurries and steam) |
Measuring range | For liquids (Water) Max. 60 to 600L/h Min. 0.1 to 0.5L/hFor gases (Air, 0°C 1,0MPa) Max. 2.2 to 22m³/h(nor) Min. 3 to 15L/h(nor) |
Fluid viscosity |
|
Fluid pressure | Max. 2.94 MPa (Option: Max. 19.6 MPa for high pressure) |
Fluid temperature | Max. 100°C (Option: Max. 250°C) Max. 85°C with alarm In case of Glass tube insert type, allowable thermal shock is 80°C |
Available material | SUS 316 or SCS14 (Options Hastelloy, Titanium etc.) |
Process connection | Rc Thread 1/4, 3/8, 1/2, 3/4 and 1 10A, 15A, 20A, 25A JIS 10 K FF Flange (Option NPT Thread , ANSI and DIN Flanges) |
Indication accuracy | 3% F.S. (5% F.S. for tapered glass tube insertion version) |
Range ability | 10 : 1 [10 : 2 for full scale of less than 3 L/h (water) or less than 100 L/h (nor) (air)] |
Alarm point | 1 point (Low or High), Open collector output Setting accuracy: ±3.0%F.S. |