The UCUF (Ultra-Clean Ultrasonic Flowmeter) series Ultrasonic Flowmeter is designed for very low flow rate applications. The nonwetted Sensor design, constructed of specific grade PFA material, makes the UCUF Series an ideal choice for semiconductor industry, where extreme cleanness of pipe line inside is of primary importance. The SFC017 is used as a converter for UCUF series ultrasonic flowmeters. Using state-of-art signal processing technology, this converter offers stable flow measurement by minimizing adverse effects caused by the bubbles contained in the flow liquids. Thus, it has achieved the reliable flow measurement of semiconductor manufacturing process and chemical liquids handling process. Furthermore, the stability of flow measurement at low flow rate has been improved significantly by the upgrading of time resolution and high speed signal processing compared to the existing products.
Features
- Next-generation upgraded chip
- 50 % smaller than conventional models.
The DIN rail bus connector reduces wiring to the power supply and RS485 connector.
The SMB connector also makes the body smaller. - Cleared EMC test: EN61326-1: 2006. RoHS compatible
- New function: Error history saving function
- Simple parameter setting
- Stronger resistance to bubbles
Specifications
Model | SFC2000-0 | SFC2000-A |
---|---|---|
Applicable detectors |
UCUF-04M, UCUF-04HM, UCUF-06M, UCUF-10M, UCUF-15M, UCUF-20M | |
Measuring fl uid | Liquids | |
Fluid temperature | 5 to 90°C | |
Fluid sound speed | 400 to 2500 m/s | |
Fluid kinematic viscosity |
0.3 to 40mm²/s | |
Flow range | Min.: 0 to 0.05 L/min, Max.: 0 to 8.0 L/min | |
Input | Sensor signal: Exclusive cable (SMB connector) | |
Pulse output | Frequency pulse output Open collector Load rating: Within 30 V DC, 10 mA Duty ratio: 1:1 Pulse rate: 0 to 1000 Hz (full scale) |
|
Current output | N/A | 4 to 20 mA DC Load resistance: Within 500 Ω |
Low flow cutoff | 0 to 25 %F.S. | |
Communication function |
RS485 communication function, Protocol: MODBUS Up to 32 units can be connected |
|
Power supply | 24V DC ± 10 % | 24V DC ± 10 % |
Enclosure | IP30 (Indoor use) | |
Installation | DIN rail installation |