NOHMI BOSAI PDCJ002-E Infrared Three-Wavelength Flame Detector

Made in Japan
Manufacturer: NOHMI BOSAI
Model: PDCJ002-E

Features of PDCJ002-E

Explosion proof

This can be used in explosion-proof areas.

High sensitivity

Catches the flame of 33 cm² normal heptane fire tray at a distance of 60 m.

Reliable fire detection

The energy intensity of the three wavelength bands in the CO₂ resonance radiation band and the flicker of the flame are judged as “fire” by an advanced algorithm to suppress false alarms.

Outdoor use

This can be installed outdoors because of dustproof and waterproof performance equivalent to IP 66.

Description of PDCJ002-E

  • NOHMI’s high-performance location lamps model FLPJ002(W) and FLPJ004(W) are used for, but not limited to, notifying occupants of the location of a manual fire alarm box.The location lamps were designed based on a new concept considering functionality, accessibility, and usability. Thanks to the new design concept, the ring-shaped location lamp FLPJ004(W) won the Japan Good Design Gold Award 2014 together with the compact-shaped FMNN, FMRN, and FMBN SERIES manual fire alarm boxes.The location lamp FLPJ004(W) is installed together with the compact manual fire alarm box, which is positioned around the manual alarm box so that the exact location of the manual alarm box can be found even in dark places.
  • The flat-shaped location lamp FLPJ002(W) should be installed on the wall just above a manual fire alarm box, to be clearly seen at a position within 10 meters from the location lamp.These location lamps without using any fragile materials are provided with a red LED lamp per unit as a light source, which has light-emitting diodes in it.
  • These location lamps can be repeatedly turned on and off within a short interval of time to indicate the hydrant pump starting by using together with the NOHMI hydrant pump starter relay box.

Specification

Type Infrared Three-Wavelength Flame Detector
Model PDCJ002-E
Explosion Proof Number Exd II CT5 (Body: Explosion proof type, Terminal: Increased safety)
Explosion-proof-type approval number TC21359
Detection wavelength band Three Wavelength bands between 4.0 μm and 5.0 μm
Detection sensitivity 33 cm² Normal Heptane Flame Detection at 60m Front Distance
(Supports 15 m, 30 m, and 45 m depending on the setting)
Detection viewing angle Horizontal and vertical 90° (The angle at which the monitoring distance is 1/2 to the front direction)
Rated voltage 24 VDC±20% (19.2–28.8 VDC) (full direct current)
Consumption current (monitoring) 90 mA or less
Consumption current (alarm) 160 mA or less when the window heater is active
Delay time Approximately 3 seconds (default), Changeable by setting
Indicator light Green 1 Hz Blinking: Normal
Yellow 1 Hz Blinking: Trouble
Red 2 Hz Blinking: Fire alarm*
Red constant: Alarm
*2 and 3 flames overlap = detection warning is about 18.5 V
Test function The contamination of the light-receiving window and the operating status of the internal circuit are checked by the pseudo-fire light, and a trouble signal is transmitted in case of an abnormality.
Contamination detection function When contamination of the light-receiving window is detected during the test and the permissible threshold is exceeded, a trouble signal is transmitted.
Power supply voltage monitoring function When the power supply voltage drops below about 18.5 V, a trouble signal is transmitted.
Connection (terminal type) Screw-type terminal (2 m pre-wired at the factory)
Connection cable specifications Heat-resistant shielded cable (HPS-1.2 / 0.9-SP)
Lead wire Approx. 2 m (ends soldered)
IP rating IP66 equivalent
Operating temperature range -20 to 60°C
(The window heater will turn on when the temperature falls below 5°C.)
Storage temperature range –30 to 70°C
Main material Aluminum alloy
Dimensions H117×W101.6×D156mm
Weight Detector: Approximately 1.3 kg
Control panel FP01021-S1 (fire/safety dedicated control panel 1 unit/circuit)
FP01041-R (For adjusting the installation angle for the detector)
ZAD019-R (weather cover SUS: Optional)
Peripherals ZPD019-R (detector cover ABS resin): For use in dusty areas (included in the installation kit)

Block diagram

PDCJ002-E

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top