Japan, Tokyo Keiso
Tokyo Keiso MAGMAX® EGC050W Converter for Electromagnetic Flow meter
Made in Japan
Manufacturer: Tokyo Keiso
Model: EGC050W
MAGMAX EGC050W is a highly-reliable separate type converter for electromagnetic flow meter with the simple design. The enhanced self-diagnostic functions provide empty pipe detection, monitoring various states of detector and much more. The easy-to-use converter in the field, EGC050W is used in combination with the MAGMAX series primary head.
Features
- Standardized high-performance functions such as pulse output, bi-directional flow measurement and status outputs including flow rate alarms
- High accuracy of ±0.5% of reading
- High speed data processing for quick response. Suitable for batch process control and pulsating flow
- The extendable excitation system allows applications to much fluid noise such as slurry
- The LCD with backlight provides 1 to 3 lines of versatile indication
- Equipped with a quick setup function to readily respond to changed flow range, pulse rate, etc.
The magnet keys allow you to alter the settings without removing the cover of conversion section - 10kHz high-speed pulse output. Capable of responding to short batch processes
Specification
Primary head for combination |
EGS1000, EGS2000, EGS4000 |
Excitation | Square wave |
Measuring range | Flow velocity: Min. 0 to 0.3m/s Max. 0 to 12m/s |
Material | Housing: Aluminum alloy
Converter cover: Aluminum alloy |
Painting | Polyurethane resin paint (Anti-corrosive painting) |
installation | Wall mount, optionally 2 inch pipe mount |
Indicator | Dot matrix LCD (With backlight) 128 × 64 pixels (59 × 31mm) Indication by initial setting1st page, indicated in 2 lines Upper line: Flow rate Lower line: Flow rate in bar-graph in % 2nd page, indicated in 3 lines |
Output | Current output: 4 to 20mA DC (Max. 22mA at burn out error mode)
Pulse output: Open collector output Pulse width: One of the following selectable |
Status output | Open collector output (Status output is selected from pulse outputs by switching.) Contents of output, Description of input and output terminal, Low flow cutoff Damping time constant, Isolation of input and output |
Standard Functions | Customer’s free measuring unit setting function, Automatic zero adjustment function, Bi-directional flow measurement function, Excitation current frequency switching function, Self-diagnosis function, Memory saves function for power fail, Testing function, Magnet key setting function |
Supply voltage | 100 to 230V AC 24V DC |
Protection class | IP66/67 (IEC 60529) |
Related Products
-
Niigara Seiki DL-S2W SERIES LEVELNIC
-
Tokyo Keiso UCUF-02M/SFC-010L Ultrasonic Flowmeter
-
TSURUMI PUMP PARTS: OIL REPLACEMENT 1 BOTTLE 8.1 OZ Parts & Accessories
-
Gentos W Star Series WS-343HD Headlight (320 lumens)
-
UHT Corporation Vitrified Grinding Wheels Abrasive Grain WA
-
Fujii Denko FS-21A-KS1 Snap Hook